Register description of the Fronius specific registers. More...
Variables | |
| struct { | |
| uint16_t res = 0 | |
| const uint16_t reg = 212 - 1 | |
| const uint16_t nb = 1 | |
| } | F_Delete_Data |
| struct { | |
| uint16_t res = 0 | |
| const uint16_t reg = 213 - 1 | |
| const uint16_t nb = 1 | |
| } | F_Store_Data |
| struct { | |
| uint16_t res = 0 | |
| const uint16_t reg = 214 - 1 | |
| const uint16_t nb = 1 | |
| } | F_Active_State_Code |
| struct { | |
| uint16_t res = 0 | |
| const uint16_t reg = 215 - 1 | |
| const uint16_t nb = 1 | |
| } | F_Reset_All_Event_Flags |
| struct { | |
| uint16_t res = 0 | |
| const uint16_t reg = 216 - 1 | |
| const uint16_t nb = 1 | |
| } | F_ModelType |
| struct { | |
| uint16_t res = 0 | |
| const uint16_t reg = 217 - 1 | |
| const uint16_t nb = 1 | |
| } | F_Storage_Restrictions_View_Mode |
| struct { | |
| uint32_t res = 0 | |
| const uint16_t reg = 500 - 1 | |
| const uint16_t nb = 2 | |
| } | F_Site_Power |
| struct { | |
| uint64_t res = 0 | |
| const uint16_t reg = 502 - 1 | |
| const uint16_t nb = 4 | |
| } | F_Site_Energy_Day |
| struct { | |
| uint64_t res = 0 | |
| const uint16_t reg = 506 - 1 | |
| const uint16_t nb = 4 | |
| } | F_Site_Energy_Year |
| struct { | |
| uint64_t res = 0 | |
| const uint16_t reg = 510 - 1 | |
| const uint16_t nb = 4 | |
| } | F_Site_Energy_Total |
Register description of the Fronius specific registers.
| struct { ... } FroniusRegisterMapFloat::F_Active_State_Code |
Current active state code of inverter - Description can be found in inverter manual
Not supported for Fronius Hybrid inverters (because of this inverter status maybe reported differently during night time compared to other inverter types)
| struct { ... } FroniusRegisterMapFloat::F_Delete_Data |
Delete stored ratings of the current inverter by writing 0xFFFF.
| struct { ... } FroniusRegisterMapFloat::F_ModelType |
Type of SunSpec models used for inverter and meter data. Write 1 or 2 and then immediately 6 to acknowledge setting.
1: Floating point 2: Integer & SF
| struct { ... } FroniusRegisterMapFloat::F_Reset_All_Event_Flags |
Write 0xFFFF to reset all event flags and active state code
| struct { ... } FroniusRegisterMapFloat::F_Site_Energy_Day |
Total energy for current day of all connected inverters [Wh].
| struct { ... } FroniusRegisterMapFloat::F_Site_Energy_Total |
Total energy of all connected inverters [Wh].
| struct { ... } FroniusRegisterMapFloat::F_Site_Energy_Year |
Total energy for last year of all connected inverters [Wh].
| struct { ... } FroniusRegisterMapFloat::F_Site_Power |
Total power (site sum) of all connected inverters [W].
| struct { ... } FroniusRegisterMapFloat::F_Storage_Restrictions_View_Mode |
Type of Restrictions reported in BasicStorageControl Model (IC124). Local restrictions are those that are set by ModBus Interface. Global restrictions are those that are set system wide.
0: local (default) 1: global
| struct { ... } FroniusRegisterMapFloat::F_Store_Data |
Rating data of all inverters connected to the Fronius Datamanager are persistently stored by writing 0xFFFF.